Position: Home > > Analytical instruments > Chromatogram > Gas chromatography > GC1120 Gas Chromatograph for Liquefied petroleum gas analysis

GC1120 Gas Chromatograph for Liquefied petroleum gas analysis

Product ID:FSqi007

Price: Please inquire PDF Format
Supply Ability:20sets/mon
Port:shenzhen
share:
  • Product Introduction
  • Consulting
  • Model NumberGC1120
    Brand NameYIMA
    Payment TermsT/T, paypal
    Characteristic
    Display screen stick out a mile.
    The microcomputer system of advanced, excellent control function
    Large capacity and high performance Column box
    High precision double stable gas path
    The sampling system flexible, to meet a variety of requirements analysis
    High sensitivity, high stability detector
    New Built-in acquisition system 
    Main technical indicators
    Temperature control
    Temperature range: room temperature 7 ° C 400 ° C ( of incremental 1 ° C )
    Temperature control object : oven , measured before and after , before and after the injection , auxiliary , 6-way
    Programming phase : seven order
    Programming rate : 0.1 ° C to 40 ° C / min ( an increase of 0.1 ° C )
    Holding time : 0 to 655min ( incremental 1min) 

    flame ionization detector ( FID )
    Sensitivity : M ≤ 8 × 10-12g / s Sample C16
    The best test results : M ≤ 3 × 10 - 12g / s sample C16
    Noise : ≤ 5 × 10-14A
    Drift : ≤ 6 × 10-13A / h
    Linear range : ≥ 106 

    Thermal conductivity detector ( TCD )
    Sensitivity : ≥ 5000mV . mL / mg sample C16
    Noise : ≤ 20μV
    Drift : of ≤ 30uV / h
    Linear range : ≥ 104 

    High sensitivity thermal conductivity detector ( HTCD )
    Sensitivity : ≥ 10000mV . mL / mg sample C16 

    Electron capture detector ( ECD )
    Detection limit : ≤ 1 × 10-13g / s Samples γ-666
    Linear range : ≥ 103
    Maximum operating temperature : 350 ° C

    Flame photometric detector ( FPD )
    Detection limit : ≤ 2 × 10-11g / s (P) Samples: methyl parathion
                    ≤ 1 × 10 - 10g / s ( S ) samples : methyl parathion 
    Nitrogen phosphorus detector ( NPD )
    Detection limit : ≤ 5 × 10 - 12g / s ( N ) Sample: azobenzene
                    ≤ 5 × 10-13g / s (P) Samples: Malathion 
    The photoelectric ionization detector ( PID )
    Detection limit : ≤ 1ppb sample : benzene

     
  • Characteristic
    Display screen stick out a mile.
    The microcomputer system of advanced, excellent control function
    Large capacity and high performance Column box
    High precision double stable gas path
    The sampling system flexible, to meet a variety of requirements analysis
    High sensitivity, high stability detector
    New Built-in acquisition system
     
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com