GC - 2001 multi-function gas chromatograph for Soil organic matter research

Product ID:FSqi013

Price: Please inquire PDF Format
Supply Ability:20sets/mon
Port:Shenzhen
share:
  • Product Introduction
  • Consulting
  • Model NumberGC - 2001
    Brand NameYIMA
    Payment TermsT/T, paypal
    Features:
    1. The high cost performance, complete double gas circuit design: can be installed simultaneously FID, TCD, FPD, or FID, TCD, ECD detector, three instruments which can be installed at the same time a packed column and a pair of capillary column, double capillary double amplifier types such as optional. Choose five kinds of detector and the methane conversion furnace, optional or quartz ceramic nozzle.
    2. Take the microcomputer system, large screen display in Chinese, five order Cheng Sheng.
    3. All temperature exceeds the turbidity automatic alarm and expired automatic power-off protection function.
    4.The detector uses unit design, with high sensitivity, low noise , good reproducibility, wide linear range of features.
    5. packed columns can be configured to various calibres , on-column injection , lined injection , capillary split / splitless .
    6. Inlet with advanced injector guides , various calibres glass capillaries lined with spring characteristics , can automatically find the equilibrium position .

    Technical Specifications:
    Temperature accuracy : ± 0.1  - ± 0.2 
    Temperature range : room temperature ± 6  --399 , in increments of 1 
    Temperature program : five bands programmed temperature , heating rate 0.1--40  / min, with increments of 0.1  and early termination of the time range : 0-255min, with 1min increments.
      Detector Sensitivity Drift Noise Scope
    FID 1×10-11g/s 0.1mv/h 0.02mv Constant , trace analysis
    TCD 3000mv.ml/mg 0.2mv/h 0.02mv Constant
    ECD 1×10-13g/ml 0.2mv/h 0.02mv Constant , trace analysis
    FPD 5×10-11g/s
    1×10-11g/s
    0.2mv/h 0.02mv Constant , trace analysis
    NPD 5×10-12g/s
    5×10-12g/s
    0.2mv/h 0.02mv Constant , trace analysis
     
  • Features:
    1. The high cost performance, complete double gas circuit design: can be installed simultaneously FID, TCD, FPD, or FID, TCD, ECD detector, three instruments which can be installed at the same time a packed column and a pair of capillary column, double capillary double amplifier types such as optional. Choose five kinds of detector and the methane conversion furnace, optional or quartz ceramic nozzle.
    2. Take the microcomputer system, large screen display in Chinese, five order Cheng Sheng.
    3. All temperature exceeds the turbidity automatic alarm and expired automatic power-off protection function.
    4.The detector uses unit design, with high sensitivity, low noise , good reproducibility, wide linear range of features.
    5. packed columns can be configured to various calibres , on-column injection , lined injection , capillary split / splitless .
    6. Inlet with advanced injector guides , various calibres glass capillaries lined with spring characteristics , can automatically find the equilibrium position .

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com