Product introduction: Fluorescence immunoanalyzer USES laser as the excitation light source. The laser is irradiated to the detection area and the quality control area of the test card. The attached fluorescent substances are excited to emit fluorescence.By detecting the fluorescence distribution of the detection area and the quality control area on the test card, the content of the substance to be measured in the samples to be tested was calculated. Performance features: Principle: double antibody sandwich immunofluorescence endpoint method Fast: results can be obtained in all projects in 10 minutes, results can be obtained in the queuing test mode of 15s, and results can be obtained in the instant mode of 5s High throughput: single channel 120 test/hour, six channel 500 test/hour Simple: the process is simple and intelligent Comprehensive: the platform can carry out more than a dozen tests without upgrading Accuracy: bioluminescence technology to ensure accurate and reliable results Repeat: repeatable detection, unlimited readings for 10-30 minutes Network: seamless connection of HIS, LIS system, comprehensive data management Multi-mode: automatic detection mode, queuing detection mode, instant detection mode Quality assurance: third party international general quality control products, no calibration required, built-in quality control system (quality control card, self-produced quality control products, PQS information system to achieve quality control) Department application Technical parameters: Input power: 100VA Excitation wavelength: 520nm to 550nm Transmitting optical filter: 570nm central wavelength Display: touch LCD display Print: built-in mini printer Interface: USB, RS232, network interface Software: meet GB/T 25000.51-2010 requirements Average trouble-free working time: over 1000h General parameters: Size: 23cm*28cm*20.5cm (length * width * height) Weight: 3.3 kg Power voltage: adapter AC 220V + / - 22V, 50Hz/60Hz + / - 1Hz; Instrument DC 12V, 4A; Input power: 100VA; The environment temperature 5 ℃ to 40 ℃; Relative humidity: 10% ~ 85%; Atmospheric pressure: 86kPa ~ 106kPa.
Product introduction: Fluorescence immunoanalyzer USES laser as the excitation light source. The laser is irradiated to the detection area and the quality control area of the test card. The attached fluorescent substances are excited to emit fluorescence.By detecting the fluorescence distribution of the detection area and the quality control area on the test card, the content of the substance to be measured in the samples to be tested was calculated.