FC110 ultra-micro UV-visible spectrophotometer Introduction:
NanoReady ultra-micro UV-visible spectrophotometer is a commonly used analytical instrument developed by our company. It is widely used in the detection of DNA, RNA and protein in molecular biological experiments. It is also used for the detection of absorbance in general material analysis. Common detection methods such as nucleic acid, UV-visible, protein, cell culture, dye markers and proteins. Variable optical path detection achieves a minimum loading of 0.5μl for precious samples, or high-concentration samples for direct detection without dilution. A cuvette detection function with heated magnetic stirring is also built in. Features:
High sensitivity
The latest generation of 2048 line CCD detection unit has higher sensitivity, accuracy and reproducibility.
2. Stability
The long-life Hamamatsu flashing xenon lamp ensures the stability of the test and the life of the instrument. The lifting and lowering detection base of the sliding bearing structure has high precision and is not easily damaged.
3. Variable optical path
Depending on the sample concentration, the instrument can automatically switch to the most suitable optical path, up to 0.05mm, so high-concentration samples can be directly detected without dilution, up to 15000ng/μL ds DNA; for precious samples, a minimum volume of 0.5μL can be used. Test. Users with a distance greater than 1mm can customize different cuvettes for flexible and convenient detection.
4. Ultra-wide wavelength range
With a continuous wavelength range of 185-910nm, any band can be selected to detect more sample types and a wider near-infrared wavelength range to accommodate a wide range of detection requirements.
5. Optical path accuracy
The stepper motor is combined with the unique dual-track precise positioning (DPTL) technology to achieve an optical path accuracy of 0.001 mm, thus achieving high repeatability of absorbance detection.
6. Cuvette detection mode
Cuvette detection mode with magnetic stirring function, and can set heating function and stirring rate for dynamic analysis and detection; user-defined 1mm, 2mm, 5mm, 10mm different optical path. (F-1100 does not have this function)
7. Uniquely designed pipetting bracket for easy loading:
Ingeniously added liquid-assisted stent to stabilize the accuracy of micro-measurement. It can be installed on both sides, and it is easy to add one-handed liquid.
8. Software features
The running interface is simple and intuitive, the function buttons are set reasonably, the data chart is displayed accurately; the test data is automatically saved, the file is automatically named, and it is convenient to look back and look, without worrying about the loss of experimental data. Set the U disk upgrade interface to keep the latest and most complete functions at any time.
9. Wireless connection
Wifi connects to PAD, controls detection and results display, storage, and bids farewell to messy data lines.
10. Multiple detection functions
a. Nucleic acid detection
Built-in commonly used dsDNA, ssDNA, RNA, Oligo-DNA, Oligo-RNA calculation formula, automatically get the sample concentration and ratio.
b. UV-visible scanning
In the full wavelength range, the wavelength to be detected is arbitrarily increased or decreased at intervals of 1 nm.
c. Detection of nucleic acid fluorescent markers
The extinction factors of commonly used fluorescent dyes of dsDNA, ssDNA, RNA, Oligo-DNA, Oligo-RNA are preset.
d. Protein detection
It can directly detect the concentration of protein solution, or detect the concentration of dye-labeled protein, and built-in commonly used detection methods such as BCA, Bradford, Lowry, and Pierce 660nm.
e. Cell detection
Automatically detect the absorbance at 600nm, and simultaneously measure the absorbance at any wavelength in the set wavelength range. Technical Parameters:
Model: FC-1100
Detection unit: 2048 pixel line CCD array
Minimum sample size (μl): 0.5
Minimum path length (mm): 0.05
Wavelength range (nm): 185-910
Wavelength accuracy (nm): ±1
Spectral resolution (nm): ≤1.8 (FWHM at Hg 253.7nm)
Absorbance accuracy: 0.002Abs (1mm pathlength)
Absorbance accuracy: ±2% (at 0.86A at 257nm)
Minimum detection concentration: 2ng/μl dsDNA
Maximum detection concentration: 15000ng/μl dsDNA
Detection time: <5 seconds
Data interface: USB
Wireless connection: Wifi
Software upgrade: U disk upgrade
Accessories: Dosing bracket
Power: AC100V-240V 50HZ/60HZ power adapter
Weight: 2.1KG
Introduction:
NanoReady ultra-micro UV-visible spectrophotometer is a commonly used analytical instrument developed by our company. It is widely used in the detection of DNA, RNA and protein in molecular biological experiments. It is also used for the detection of absorbance in general material analysis. Common detection methods such as nucleic acid, UV-visible, protein, cell culture, dye markers and proteins. Variable optical path detection achieves a minimum loading of 0.5μl for precious samples, or high-concentration samples for direct detection without dilution. A cuvette detection function with heated magnetic stirring is also built in.