EDX-6000 Energy Dispersive X-Fluorescence Spectrometer
Introduction: EDXRF energy dispersive X-ray fluorescence spectrometer is used in RoHS, alloys, precious metals, soil heavy metals, waste liquid heavy metals, central laboratory finished product inspection and other fields. EDX-6000 Energy Dispersive X-Fluorescence Spectrometer is small in size, good in stability, fast and accurate in analysis, low in operating cost, convenient in operation and maintenance, and can detect all elements from S(16)-U(92). The large sample chamber design of the EDX-6000 fluorescence spectrometer is suitable for the testing of samples of various types (solid, liquid, powder, film, etc.) and shapes (blocks, sheets, lines). The EDX-6000 fluorescence spectrometer is specially designed to test the five elements Cd, Pb, Hg, Br, Cr and the halogen element Cl involved in the six substances in the EU RoHS Directive. Extended interfaces are provided for further elemental analysis, from sulfur to uranium. Technical parameter: Instrument model: EDX-6000 Detection limit: 2ppm Analysis element range: S(16)—U(92) any element Vacuum system: non-vacuum Sample Type: Solid/Powder/Liquid X-ray tube: Mo/W/Ag/Rh and other targets are optional X-ray tube: Tube voltage: 5—50kv Tube current: 1—1000uA Inner cavity size: 450mm*330mm*100mm Collimator: 2, 5, 8mm Detector: Si-PIN detector High Voltage Generator: SPELLMAN High Voltage Generator ADc: Lane 2048 Filter: 6 kinds of filters are automatically selected and automatically converted Sample observation: 1.3 million color CCD camera Analysis software and methods: free upgrade for life, theoretical alpha coefficient method, basic parameter method, empirical coefficient method Working environment: temperature 10-35℃, humidity 30-70%RH atmospheric environment Dimensions and weight: 600(W)×500(D)×430(H)mm 5okg (host part) External power supply requirements: AC220+10%, 50/60Hz Test sample time: 0-300 seconds adjustable
Introduction: EDXRF energy dispersive X-ray fluorescence spectrometer is used in RoHS, alloys, precious metals, soil heavy metals, waste liquid heavy metals, central laboratory finished product inspection and other fields. EDX-6000 Energy Dispersive X-Fluorescence Spectrometer is small in size, good in stability, fast and accurate in analysis, low in operating cost, convenient in operation and maintenance, and can detect all elements from S(16)-U(92). The large sample chamber design of the EDX-6000 fluorescence spectrometer is suitable for the testing of samples of various types (solid, liquid, powder, film, etc.) and shapes (blocks, sheets, lines). The EDX-6000 fluorescence spectrometer is specially designed to test the five elements Cd, Pb, Hg, Br, Cr and the halogen element Cl involved in the six substances in the EU RoHS Directive. Extended interfaces are provided for further elemental analysis, from sulfur to uranium.