DMS-100 Low Range Extraction Dust Monitor Introduction: The DMS-100 low range extraction dust monitor mainly uses laser forward scattering measurement technology, which is suitable for ultra-low emission scenarios. Application: Suitable for ultra-low emission scenarios Features: 1. Using laser forward scattering measurement technology to measure low detection limit dust concentration 2. Use compressed air to sweep the laser and detector lens and clean the flow channel 3. Support for dual range switching 4. Easy to install specifications Range: 0-10mg/m3, 50mg/m3 (customizable) Drift: ± 2% F S. Indication error: ± 20% Response time: 10s Protection level: IP65 Detection limit: 0.1mg/m3 Smoke humidity: relative humidity 0-100% RH (non condensing) Smoke pressure: -2KPa~1KPa Temperature: < 300 ℃