Introduction: DLSC-N full network temperature monitoring system is a set of visible light, infrared thermal imaging and embedded processing technology in one of the real-time monitoring and control system, the system can run on the substation equipment automatic inspection, real-time monitoring, automatic warning, real-time Get the thermal information of the equipment fault status and automatically generate the corresponding temperature change report. It has the characteristics of uninterruptible power supply, long distance, safe and reliable, high detection accuracy and is a very effective means for online monitoring and equipment status maintenance. Features: 1. Temperature measurement fast, accurate, good uniformity Infrared image compression and network transmission 3. The world's leading substation equipment intelligent identification system Auto cruise 5. All kinds of security, events, equipment and other management functions 6. Normal operation under bad weather 7. Automatically generate reports 8. Fully compatible with IEC61850 protocol 9. System integration easy Technical Parameters: Detector type: uncooled focal plane micro-thermal type Pixels: 384 × 288 Thermal sensitivity: ≤ 0.06 ℃ @ 30 ℃ Frame rate: 50 / 60Hz Focus: Auto / manual focus Wavelength range: 8 ~ 14μm Zoom factor: 30x optical zoom Image resolution: 2 million pixels, 1080P Minimum illumination: 0.005 (Lux) Horizontal rotation angle: 0 ° ~ 360 ° continuous rotation Presets: Support 255, support for angle feedback Bearing and movement range: Top load: -90 ° ~ + 90 ° Temperature range: -20 ℃ ~ + 650 ℃ Accuracy: ± 2 ℃ or ± 2% (reading range), whichever is greater Temperature correction: automatic / manual Measurement mode: arbitrary software settings The original image acquisition: back-end manual collection of single-frame, 25-frame raw data images, data collected image analysis, temperature measurement Image Storage: H.264 network video digital storage, transmission Single photo save, BMP format External power supply: 220AC Power consumption: ≤ 75W (25 ℃ normal working hours) Operating temperature: -40 ℃ ~ +65 ℃ Protection level: IP66 Humidity: ≤90% (non-condensing)
Introduction: DLSC-N full network temperature monitoring system is a set of visible light, infrared thermal imaging and embedded processing technology in one of the real-time monitoring and control system, the system can run on the substation equipment automatic inspection, real-time monitoring, automatic warning, real-time Get the thermal information of the equipment fault status and automatically generate the corresponding temperature change report. It has the characteristics of uninterruptible power supply, long distance, safe and reliable, high detection accuracy and is a very effective means for online monitoring and equipment status maintenance.