CS-720 intelligent and efficient haze meter Introduction: It is suitable for one-stop measurement solutions of clarity, color, haze, spectral transmittance, and total transmittance of transparent and translucent materials such as plastics, films, glass, LCD panels, and touch screens. Features: 1. Has a wealth of measurement parameters, providing professional clarity measurement function 2. Has comprehensive color measurement function in the industry 3. Follow ASTM and ISO standards 4. Provide multiple measurement light sources 5. Compensation method measurement to make the data more accurate 6. Standard computer data analysis and management software 7. 7-inch Android system touch screen, providing a better test experience 8. The open sample compartment can be measured horizontally or vertically, how convenient it is 9. Provide abundant measuring fixtures technical parameter: Model: Clarity Haze CS-720 Light source: Haze/transmittance: CIE-A, CIE-C, CIE-D65 Chromaticity index: A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CMF, U30, DLF, NBF, TL83, TL84 Follow standards: ASTM D1003/D1044, ISO13468/ISO14782, JIS K 7105, JIS K 7361, JIS K 7136, GB/T 2410-08, CIE No. 15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c standard Measurement parameters: haze (HAZE), transmittance (T), spectral transmittance, clarity (C%) CIE Lab, LCh, CIE Luv, XYZ, Yxy,, Hunter Lab MunsellMI, CMYK, Whiteness WI (ASTM E313-00, ASTM E313-73, CIE/ISO, Hunter, Taube Berger Stensby), Yellowness YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Tint (ASTM E313-00), the metamerism index Milm, APHA, Pt-Co (Platinum Cobalt Index), Gardner (Gardner Index), color difference (ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1) ,ΔE*94,ΔE*00) Measuring range: 0-100% (haze, transmittance, clarity) Spectral response: CIE spectral function Y/V(λ) Wavelength range: 400-700nm Wavelength interval: 10nm Light path structure: 0/d Illumination and sample aperture size: 16.5mm/21mm Range: 0-100% Resolution: 0.01 unit Repeatability: Haze <10%, repeatability ≤0.05%; Haze ≥10%, repeatability ≤0.1%; Light transmittance ≤0.1% Sample size: thickness≤145mm Display: 7-inch capacitive touch screen Stored data: 20000 values Interface: USB interface Power supply: 220V (with power cord) Working temperature: 0~45℃, relative humidity 80% or lower (at 35℃), no moisture condensation Storage temperature: -25℃~55℃, relative humidity 80% or lower (at 35℃), no moisture condensation Volume (length X width X height): 598mmX247mmX366mm Standard: PC management software (Haze QC) Optional: measuring fixture, haze standard film, clarity standard film, 5mm/7mm/10mm caliber plate, 40*10 cuvette
Introduction: It is suitable for one-stop measurement solutions of clarity, color, haze, spectral transmittance, and total transmittance of transparent and translucent materials such as plastics, films, glass, LCD panels, and touch screens.