1 Sales CL1040 Fully Automatic Capillary Electrophoresis,Manufacturer
Position: Home > > Analytical instruments > Chromatogram > Capillary electrophoresis > CL1040 Fully Automatic Capillary Electrophoresis for Biochemical Research

CL1040 Fully Automatic Capillary Electrophoresis for Biochemical Research

Product ID:FSmao005

Price: US$16,000.00 ~ US$30,000.00 PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberCL1040
    Brand NameYIMA
    Payment TermsT/T, paypal
    CL1040 Fully Automatic Capillary Electrophoresis
    Introduction:
    Charged particles in the DC electric field under a certain medium will occur in directional movement, the use of this phenomenon on the chemical or biochemical components of the separation and analysis of technology called electrophoresis. Our company according to the principle of production CL1040 automatic capillary electrophoresis instrument, matching a variable wavelength of light absorption of domestic UV detector. The detector has the functions of automatic wavelength positioning adjustment, automatic zeroing, time constant selection, constant temperature and automatic sampling. It is widely used in environmental protection, biochemistry, medical hygiene, clinical testing, justice, food hygiene, drug testing, agricultural chemistry And other fields.
    Instrument features:
    High separation efficiency, fast analysis speed, high detection sensitivity,
    Reagent dosage is small, sample pretreatment is simple, washing method: automatic pressure washing
    Microprocessor control, high wavelength repeatability, wide detection range
    Variable wavelength selection, 190 ~ 700nm continuously adjustable
    LCD screen display, touch panel, program to find the wavelength, automatically zero
    Unique deuterium lamp temperature control, deuterium lamp life of not less than 2000 hours
    Injection method: electric sample 0 ~ 30KV or 0 ~ -30KV (select negative power) adjustable, pressure injection 0.5 ~ 50kpa adjustable
    Automatic temperature control temperature range: 10 ℃ to room temperature, temperature range 1 ℃, stability ± 1 ℃
    Technical indicators:
    UV detector
    Optical system: imported design diffraction grating monochromator, imported photovoltaic cells
    Light source: deuterium lamp (standard), at least 2000 hours
    Wavelength range: 190 ~ 700nm, continuously adjustable
    Wavelength Accuracy: ± 2nm;
    Qualitative repeatability: RSD ≤ 1.5%; Quantitative repeatability: RSD ≤ 3.0%
    Attenuation range: 0.1,0.2,0.5,1.00,2.00,5.00, 5 files available
    Noise: ± 1.5 × 10-5 AU (254nm)
    Drift: ± 4 × 10-4 AU / h (254nm)
    Detection limit: ≤ 1 × 10-7g / ml (imidazole)
    High voltage power supply:
    Output voltage: 0 ~ 30KV, the program control continuously adjustable (positive voltage range)
    Output voltage: 0 ~ -30KV, the program control continuously adjustable (negative voltage range) (optional)
    Output current range: 0 ~ 999μA
    Can be programmed to adjust the voltage and output; boot can output a stable voltage, no preheating, voltage output continuously adjustable, set the program after the automatic voltage regulator, voltage and current output from the digital table continuous display, to voltage, time, overload current , Group and section of the level of setting and monitoring.
    Power regulation: ± 10% change in supply voltage, 0.01% change in output voltage
    Load regulation: 10V / 100μA
    Ripple: 0.1% of output voltage P-P
    Voltage indication error: ≤ 2.0% current indication error: ≤ 3.0%
    Stability change: ≤1.5%
    Injection system and thermostat system:
    Constant temperature mode: forced solid temperature
    Temperature control: 10 ℃ to room temperature, temperature range 1 ℃, stability ± 1 ℃
    Electric injection: voltage 0 ~ 30KV or 0 ~ -30KV (select negative power) adjustable, duration 1 ~ 5940sec
    Pressure injection: pressure 0.5 ~ 50.0kpa, duration 1 ~ 999sec, pressure repeatability 1%
    Injection device: test tube automatic positioning, 15 to 20 injection test tube position

  • Introduction:
    Charged particles in the DC electric field under a certain medium will occur in directional movement, the use of this phenomenon on the chemical or biochemical components of the separation and analysis of technology called electrophoresis. Our company according to the principle of production CL1040 automatic capillary electrophoresis instrument, matching a variable wavelength of light absorption of domestic UV detector. The detector has the functions of automatic wavelength positioning adjustment, automatic zeroing, time constant selection, constant temperature and automatic sampling. It is widely used in environmental protection, biochemistry, medical hygiene, clinical testing, justice, food hygiene, drug testing, agricultural chemistry And other fields.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com