Technical indicators: Circumferential magnetization current: AC 0-2000 - a continuous adjustable, with power phase control (no residual). Longitudinal magnetization of magnetic potential: AC 0-18000 at continuous adjustable, with power control (not miss). Electrode gap: 0-200 mm. Magnetization principle: electricity, magnetic yoke method. The circumferential magnetization magnetization way: three artifacts respectively electricity (with alarm systems, three respectively report to the police), longitudinal magnetization, three kinds of magnetization can be flexible to choose. Using the environment: - 10 ℃ - + 40 ℃, relative humidity 80% or less. Storage environment: temperature - 20 ℃ to 60 ℃, relative humidity 70% or less. No corrosive gas dust and strong high frequency electromagnetic pollution. Uv intensity: ultraviolet intensity is 380 mm from the workpiece in not less than 1000 mu W/cm2. Sensitivity test: according to the law of the People's Republic of China machinery industry standard JB/T6065-92 "standard specimens with magnetic powder flaw detection" regulation, with standard specimens 2 type A test, show clear. Power supply: three phase four wire, 380 v + 10%, 50 Hz, about 80A.
Technical indicators: Circumferential magnetization current: AC 0-2000 - a continuous adjustable, with power phase control (no residual). Longitudinal magnetization of magnetic potential: AC 0-18000 at continuous adjustable, with power control (not miss). Electrode gap: 0-200 mm. Magnetization principle: electricity, magnetic yoke method.