1 Sales BT-2016C Round and Square Battery Cell Test System,Manufacturer
Position: Home > > Analytical instruments > Electrochemistry > Other electrochemical apparatus > BT-2016C Round and Square Battery Cell Test System

BT-2016C Round and Square Battery Cell Test System

Product ID:FDqtOther020

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberBT-2016C
    Brand NameGERUISI
    Payment TermsT/T, paypal
    BT-2016C Round and Square Battery Cell Test System
     
    Introduction:
     1. Application areas:
    The technical department and quality department of the battery manufacturer are responsible for battery materials, primary batteries (cells), PACK batteries,
    C. Sampling and testing of digital products and other batteries.
    2. Test items:
    Test research on cylindrical batteries, square batteries, polymer batteries, etc. Test battery capacity, specific capacity, charge-discharge curve, cycle life, charge-discharge efficiency, etc.
     3.Range selectable
    Voltage range: 3V \ 5V \ 6V \ 7V \ 10V \ 15 \ 18V
    Current range: 200MA \ 50MA \ 1A \ 2A \ 3A \ 5A \ 10A
    Technical Parameters:
    Test channels: The number of channels is 8 channels / set; independent control, independent programming, and no interference with each other
    System power: AC: 220V / 50Hz; 300W / set
    Measuring range: Charging voltage: 0V --- 3V (5V, 6V, 7V, 10V, 15V, 18V continuously adjustable)
    Discharge voltage: 0V or 2.5V (customized according to requirements)
    Current range: full range * 0.1%-full range (continuously adjustable)
    Test accuracy: Voltage: ± (0.05% RD + 0.05% FS)
    Current: ± (0.05% RD + 0.05% FS)
    Display digits: 6 significant digits
    DA / AD: 16-bit / 14-bit (currently highest level)
    Data sampling speed: 1 line / second
    Test method: Four-wire measurement (voltage and current are sampled separately)
    Control mode: High-precision linear adjustment Constant current source and constant-voltage source adopt double closed-loop structure, high-precision linear adjustment
    Safety protection: a. The system hardware itself is designed with over-current and over-voltage protection;
    b. The system is protected against power failure. When the power is turned on, the data is automatically backed up at regular intervals.
    c. Protection condition setting: first time delay protection over, voltage protection, over current protection, over capacity protection, temperature protection
    DCIR test: Supports custom pick points for DCIR calculation
    Data sampling method: a. Time t: 10ms --- 3600S (time variation)
    b. Voltage U: 1mV --- 50V (Voltage change)
    c. Current I: 10uA--5000mA (current change amount)
    Working mode: Charging: constant current charging, constant voltage charging, rate charging, constant power charging, standing
    Discharge: constant current discharge, constant power discharge, constant resistance discharge, rate discharge
    (8 working modes for smart form editing, 11 ending conditions, 4 data recording conditions, loop nesting, variable programming, etc.)
    Three-electrode test: support
    Number of cycles: 1-99999 times
    Loop nesting: with nested loop function, supports up to 3 levels of nesting
    Cooling method: Air-cooled (fan speed is controlled with temperature)
    Data export method: Excel, Txt
    Communication method: RS232 / RS485 / RJ45
    Software control mode: Support: run, stop, auto-continue, jump, restart, force jump, reset operation parameters online, etc .;
    Channel input impedance: 10GΩ (leakage current <0.1nA in static state)
    Working environment temperature: -10 ~ 60
    Working environment humidity: 80% RH (without condensation)
    Fault-free operation time: 24 months (continuous)
    Battery holder: The box comes with a thimble holder (square or cylindrical battery), crocodile holder, polymer holder, etc. (user selectable)
    Single device size: length × width × height = 49cm × 38cm × 13cm
    Single equipment weight: 10Kg

     
     
     
  •  1. Application areas:
    The technical department and quality department of the battery manufacturer are responsible for battery materials, primary batteries (cells), PACK batteries,
    C. Sampling and testing of digital products and other batteries.
    2. Test items:
    Test research on cylindrical batteries, square batteries, polymer batteries, etc. Test battery capacity, specific capacity, charge-discharge curve, cycle life, charge-discharge efficiency, etc.
     3.Range selectable
    Voltage range: 3V \ 5V \ 6V \ 7V \ 10V \ 15 \ 18V
    Current range: 200MA \ 50MA \ 1A \ 2A \ 3A \ 5A \ 10A

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com