    BS-160A automatic part collector 
    Introduction:
    The automatic partial collector is also called component collector and fraction collector. It is one of the basic equipment for biochemical experiments and biopharmaceutical production. It is used to automatically and quantitatively collect the droplets flowing out of the chromatography column to achieve the loading of different active components. Go in different test tubes for the purpose. The Jiapeng automatic partial collector is a device that automatically separates the solution separated from the chromatography tube according to the quantitative when using chromatographic method to separate some mixed substances. In the phase chromatographic layer analysis experiment, this instrument can automatically collect the chromatographic liquid in fractions, instead of manual operation, and improve work efficiency. It is combined with the Jiapeng nucleic acid protein detector/ultraviolet detector, constant flow pump, chromatography column and data workstation to form a set of liquid Phase chromatography separation chromatography system. This series of automatic partial collectors adopts a new microcomputer chip, which can automatically collect regularly, collect drops by counting, record peak sampling and collect chromatographic fluids, realize automatic sampling collection, improve collection quality and work efficiency, and are deeply engaged in scientific research by scientific research institutions and factories and mining enterprises. The ideal instrument produced has been widely used in tertiary institutions such as Tsinghua University, Peking University and Fudan University.
    Features:
    1. It is made of fully enclosed environmentally-friendly molecular strength ABS material, and the injection mold is sub-formed, which is firm and beautiful;
    2. The design of the control panel with an oblique angle of 35° is ergonomic and can be easily controlled without having to bend over;
    3. Digital tube LED display mode, new microcomputer chip control;
    4. Unique collection tray digital marking design, each test tube corresponds to a number, to ensure that the test tube is taken out of the tube;
    5. Collection function: automatic collection, can be arbitrarily selected, collection and tube replacement does not deviate, tube replacement positioning;
    6. Timing function: the collection time, the timing of inversion and timing can be selected arbitrarily, and the test tube trays of the same specification can be freely interchanged, without the need to check in place;
    7. Parameter setting function: arbitrarily set parameters, setting pipes and end pipes;
    8. Using keebio fluid shut-off valve, the test tube tray is resistant to organic solvents (optional);
    9. External trigger function: the dedicated COM interface is directly connected to control the constant flow pump for supporting use.
    Technical parameter:
    Product model: BS-160A
    Collection test tubes: 160
    Capacity: 5ml
    Display mode: digital tube
    Timed collection range: 1 second -199 hours 59 minutes 59 seconds, any choice
    Test tube tray: round numbered test tube tray
    Power-off data storage: ten years
    Continuous working time: more than 200 hours

  • Introduction:
    The automatic partial collector is also called component collector and fraction collector. It is one of the basic equipment for biochemical experiments and biopharmaceutical production. It is used to automatically and quantitatively collect the droplets flowing out of the chromatography column to achieve the loading of different active components. Go in different test tubes for the purpose. The Jiapeng automatic partial collector is a device that automatically separates the solution separated from the chromatography tube according to the quantitative when using chromatographic method to separate some mixed substances. In the phase chromatographic layer analysis experiment, this instrument can automatically collect the chromatographic liquid in fractions, instead of manual operation, and improve work efficiency. It is combined with the Jiapeng nucleic acid protein detector/ultraviolet detector, constant flow pump, chromatography column and data workstation to form a set of liquid Phase chromatography separation chromatography system. This series of automatic partial collectors adopts a new microcomputer chip, which can automatically collect regularly, collect drops by counting, record peak sampling and collect chromatographic fluids, realize automatic sampling collection, improve collection quality and work efficiency, and are deeply engaged in scientific research by scientific research institutions and factories and mining enterprises. The ideal instrument produced has been widely used in tertiary institutions such as Tsinghua University, Peking University and Fudan University.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com