Position: Home > > Physical property test > Testing machine > Torsional / bending test machine > BR-PV-RT leading out end strength tester

BR-PV-RT leading out end strength tester

Product ID:WSHnw015

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberBR-PV-RT
    Brand NameYM
    Payment TermsT/T, paypal
    Implementation of standards:
    IEC 60068-2-21:2006, IEC 61215:2005 & Ed.3, IEC 61646:2008, UL 1703-2008, VDE 0126-5:2008...
    Ua1 Tensile test: Note: Ua2 for pressure test, does not apply to junction box
    Poise weight or traction force with tolerance 40N±10%
    Test subject: type A,B,C terminations. 
    Ub Bending test: 20N
    The end of test sample hanging poise 20N±10%
    Can be fixed module, vertical plane rotation.
    The termination shall assume, during the course of the test, a displacement of at least 30° with respect to its initial position. over a period of 2~3s, through an angle of approximately 90° in the vertical plane and then returned to its original position over the same period of time; this operation constitutes one bend. this operation constitutes one bend. Automatic finish 10 cycles.
    Two bends in the same direction without interruption, or a larger number of alternate bends where prescribed in the relevant specification. No device capable of imposing a radius of curvature shall be placed between the body of the component and the point of application of the force. Strip terminations shall be bent perpendicularly to the widest surface of the strip.
    Strain Relief Test: 89N UL 1703-2008
    Ud Torque test:
    IEC 61215 & IEC 61646 as described in IEC 60068-2-21:2006 test Ud, with the following provisions:
    —all terminations shall be tested
    —severity 1
    The nuts or screws should be capable of being loosened afterwards unless they are specifically designed for permanent attachment.
    Nominal thread diameter mm 2.6 3.0 3.5 4.0 5.0 6.0 8.0
    Torque N·m - Severity 1 0.4 0.5 0.8 1.2 2.0 2.5 5.0
     
  • Implementation of standards:
    IEC 60068-2-21:2006, IEC 61215:2005 & Ed.3, IEC 61646:2008, UL 1703-2008, VDE 0126-5:2008...
    Ua1 Tensile test: Note: Ua2 for pressure test, does not apply to junction box
    Poise weight or traction force with tolerance 40N±10%
    Test subject: type A,B,C terminations. 

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com