Introduction: BluPAD LED Blue and White Dual Light Source Observing Device (Cut-Glue Detector) is a dual-light source light box that is applicable to various life science research fields and is applied to the observation and analysis of nucleic acids, proteins and other materials. After the application of observation, for example: Cutting plastics, photo archiving, etc. are optimized and user-friendly designs, and it is expected to provide a comfortable, convenient and safe new experience on the interface of the researcher. The blue light mode uses a blue LED with a special wavelength of 470nm as the excitation light source. It can be used for the qualitative and quantitative analysis of nucleic acids or proteins after staining with fluorescent dyes. It can use safety reagents such as: SYBR Gold, SYBR Green I & II, SYPRORuby , SYPRO Orange, and Coomassie Fluor Orange stains, GelStar, GelGreen Novel Juice, Novel Green, Novel Green Plus, One PCR series, Nimble Juice, Nimble Juice RTYPE and other fluorescent dye products. The three-segment brightness adjustment function can adjust the brightness according to the sample content to achieve the best picture quality. Magnetic amber filter, hingeless design is easy to open and close, simple and safe. Features: 1. Dual light source design. Wide range of applications, high applicability, suitable for basic science and medical diagnosis related fields. 2.Magnetic filter design. The hingeless design is easy to use, safe and convenient. You don't need to wear glasses to observe and cut the glue. It will not damage the filter at the hinge. 3. The LED bottom light design avoids scattering diffraction interference caused by side light emission, enhances observation and picture quality, LED is durable and safe, no UV radiation can cause human eye skin damage or cause damage to experimental samples. 4. Three-stage dimming design. Adjust the brightness contrast according to the sample size or observation requirements to achieve the best observation or picture quality 5. Automatic power-off design in 5 minutes. Protect the machine to avoid the danger caused by the loss of personnel. 6. The metal body design base is more stable and operates more smoothly. 7. Ingenious design. It is convenient to carry the collection and it is suitable for the investigation and observation of the outing. 8. Support external mobile power Technical Parameters: Volume (width*length*height): 18.5 x 22 x 3cm Observable range (width * length): 12 x 18cm Input voltage: 100-240Vac Input current: 2.0A LED light source: Built-in blue light & white light LED module Built-in Blu-ray/White LED module LED Lifetime (hours): >30,000 Light emitting wavelength: 470nm Storage temperature: 25° C Automatic shutdown: 5 mins Filter Specifications: Amber filter ( 580nm )
Introduction: BluPAD LED Blue and White Dual Light Source Observing Device (Cut-Glue Detector) is a dual-light source light box that is applicable to various life science research fields and is applied to the observation and analysis of nucleic acids, proteins and other materials. After the application of observation, for example: Cutting plastics, photo archiving, etc. are optimized and user-friendly designs, and it is expected to provide a comfortable, convenient and safe new experience on the interface of the researcher. The blue light mode uses a blue LED with a special wavelength of 470nm as the excitation light source. It can be used for the qualitative and quantitative analysis of nucleic acids or proteins after staining with fluorescent dyes. It can use safety reagents such as: SYBR Gold, SYBR Green I & II, SYPRORuby , SYPRO Orange, and Coomassie Fluor Orange stains, GelStar, GelGreen Novel Juice, Novel Green, Novel Green Plus, One PCR series, Nimble Juice, Nimble Juice RTYPE and other fluorescent dye products. The three-segment brightness adjustment function can adjust the brightness according to the sample content to achieve the best picture quality. Magnetic amber filter, hingeless design is easy to open and close, simple and safe.