AS1560 intelligent 3D motion automatic sampler Introduction: The intelligent 3D motion automatic sampler, linked with the ion chromatograph host system, can automatically start the injection program after baseline equilibrium, and has the function of single channel and dual channel simultaneous injection. Supports fully automatic dilution and standard curve preparation functions. Features: 1. Needle washing program: Independent needle washing position, reverse emptying design can blow and empty the cleaning solution in the injection needle and pipeline in reverse after washing the needle; 2. Door opening protection: During the operation of the sampler, the actions of the rotating needle, turntable, up and down needles, etc. that are currently running after the chamber door is opened, will pause. After the door is closed, all actions will continue without affecting the work; 3. Sample bottle missing response: When the sample bottle is missing at the injection position, it can be accurately detected. The bottle missing alarm function is activated, and the missing bottle position is recorded and automatically skipped for the next sequence of operation; 4. No sample/cleaning solution detection: When there is no sample loaded in the sample bottle or the cleaning solution is missing, it can be accurately detected and recorded. The response method can be programmed to skip this position or stop the sampler operation; 5. Protection against movement disorders: When a foreign object gets stuck in the sample tray, causing obstacles to the turntable, or when the injection needle punctures a solid cover or a hard object, causing obstacles to the needle insertion, it can automatically detect obstacles and record and respond to the automatic stop of the sampler, avoiding damage to the turntable or injection needle. 6. Operation records: The command records, injection records, alarm records, and door opening records of the sampler can be uploaded and saved in real time, and the operation process can be traced; Technical parameters: Instrument model: AS1560 Number of sample bottles: 85 Sample bottle volume: 12mL Injection repeatability: RSD ≤ 0.5% Cross contamination: ≤ 0.003% Injection method: full loop injection Maximum injection volume: 12mL (determined by the quantitative ring) Number of injection channels: Dual channel optional Input/output interfaces: RS232, RS485, switch input, switch output Power requirements: 220V ± 10%, 50-60Hz Weight: 18Kg Dimensions: 390mm (width) * 435mm (height) * 500mm (depth)
Introduction: The intelligent 3D motion automatic sampler, linked with the ion chromatograph host system, can automatically start the injection program after baseline equilibrium, and has the function of single channel and dual channel simultaneous injection. Supports fully automatic dilution and standard curve preparation functions.