AM-5800 Dynamic Calibrator Introduction: Dynamic calibrator is a multi-channel gas calibration instrument based on microprocessor technology, specifically developed for precision gas analyzers. The calibrator uses a high-precision mass flow controller and standard gas to provide calibration standard gas for zero and range testing of various gas parameters, while also providing four gas sources. The dynamic calibrator can be equipped with a programmable ozone generator, which can be used not only for accurate and reliable ozone calibration, but also for GPT generation of NO2. The ozone generator adopts multi-point segmented linear drive to ensure the repeatability and accuracy of ozone concentration; The optional photometer can also provide higher precision control of the ozone generator. The dynamic calibrator has fast response, high repeatability, high accuracy, and is convenient to use. Customization can also be made according to customer requirements. Features: 1. Continuous self check with alarm function 2 high-precision Swiss mass flow controller, high dilution rate, fast response 3 quartz gas phase titration gas chambers with multiple calibration gas interfaces 4 optional ozone emitters and ozone photometers 5 color screen display, touch operation, large capacity memory, automatic storage of historical data 6 applications are used together with zero gas generators to provide quality assurance for laboratories and gas analyzers. Technical parameters: Dilution gas flow range: 0-10SLPM Calibration gas flow range: 0~100SCCM Flow control accuracy: ± 1% F.S. Linear flow control: ± 0.2% F.S. Repeatability of flow control: ± 0.2% F.S. Dilution gas flow demand: 10SLPM@30psi Response time: < 180s (T98) Environmental temperature: 5 ℃~40 ℃ Size: 178mmx430mmx630mm Weight: 14.06kg (basic unit) Power: 200V~240V, 50/60Hz, 400W Analog output: 10V, 5V, 1V, 0.1V (optional) Communication: RS232, RS485
Introduction: Dynamic calibrator is a multi-channel gas calibration instrument based on microprocessor technology, specifically developed for precision gas analyzers. The calibrator uses a high-precision mass flow controller and standard gas to provide calibration standard gas for zero and range testing of various gas parameters, while also providing four gas sources. The dynamic calibrator can be equipped with a programmable ozone generator, which can be used not only for accurate and reliable ozone calibration, but also for GPT generation of NO2. The ozone generator adopts multi-point segmented linear drive to ensure the repeatability and accuracy of ozone concentration; The optional photometer can also provide higher precision control of the ozone generator. The dynamic calibrator has fast response, high repeatability, high accuracy, and is convenient to use. Customization can also be made according to customer requirements.