AKF-BT2015C Karl fischer microscale moisture meter Brief introduction
AKF-BT2015C Coulomb method, the detection accuracy of 0.1ug, the detection results of repeatability is excellent; the instrument is suitable for direct detection of trace moisture in the liquid, and can also be determined by heating the sample in the sample. In the detection process, there is no need to puncture the pad, the sample bottle can be used repeatedly, and the material loss is small. Gas export pipeline design of small size, no residual, no memory effect, with heating with tube to prevent condensation of water vapor operation is simple, automatic deduction of drift, simplify the calculation operation, the end of the test automatically calculate the water content. Features
1. Cassette headspace vials heating technology, effective way to avoid heating furnace and a reaction cup pollution, using 10 ml, 20 ml can be reused sample bottle, only need to put the weight of the sample is placed in the sample bottle can be.
2. The original sample bottle connector, so that the carrier gas without puncture into the sample bottle. It is not only into the sample bottle, good sealing, and can be disassembled easily!
3 accurate flow control design, gas consumption is only 1/10 of the same kind of imported products, save gas consumption at the same time, to ensure that no longer the sample is carried out into the pipeline system;
4 high power cooling tank design, rapid cooling of the sample bottle, improve working efficiency;
5.7 "high resolution color touch screen interface, multi parameter display, intuitive and simple; a key determination, the operation is very simple, no special training can be started;
6 no dead volume design of the anti condensation heat insulation pipe, ensure that the water pipe wall system without evaporation, and completely into the reaction cup;
7 heating temperature up to 300 degrees, 0-100ml gas flow rate of freedom to adjust, meet the needs of most of the solid raw material moisture determination;
8 automatic constant current polarization detection, no need to manually set the end point, the detection accuracy is high, the water measurement resolution of 0.1ug;
9 using Kulun titration detection principle, the 6 speed can be adjusted, and the application of different intensity of Carle Fei reagent, determination of speed; Technical parameter
Measurement range: 3ug-99mg (H2O weight)
Determination of Carle:'s fee for the rest of the Coulomb method
Sample heating method: bottle type heating
Injection needle size: 0.3mm
Resolution: 0.1ug (H2O quality)
Host display size: 7 "color touch screen
The parameter display: water content, moisture percentage of ppm in the sample, the absolute value of water consumption, cassette reagent volume
Repeatability: > 99.7% (1000 g pure water)
Sample measurement time: average 50 seconds to a few minutes
Flow range: 0-100ml/min (0.1Mpa)
Temperature range: RT~280℃
Data storage: automatic storage of data 200
Print function: special external printer (optional)
Language: English and Chinese
Calibration function
Automatic function: automatic balance, automatic background subtraction, automatic calculation of the results of the preservation
Ambient temperature: 5 ~ 40℃
Environment temperature: 20 ~ 80%
Brief introduction
AKF-BT2015C Coulomb method, the detection accuracy of 0.1ug, the detection results of repeatability is excellent; the instrument is suitable for direct detection of trace moisture in the liquid, and can also be determined by heating the sample in the sample. In the detection process, there is no need to puncture the pad, the sample bottle can be used repeatedly, and the material loss is small. Gas export pipeline design of small size, no residual, no memory effect, with heating with tube to prevent condensation of water vapor operation is simple, automatic deduction of drift, simplify the calculation operation, the end of the test automatically calculate the water content.