1 Sales AKF -2010V intelligent Karl fischer moisture meter instrument,Manufacturer
Position: Home > > Analytical instruments > Moisture teller > Infrared / halogen moisture analyzer > AKF -2010V intelligent Karl fischer moisture meter instrument

AKF -2010V intelligent Karl fischer moisture meter instrument

Product ID:FSHhwls007

Price: Please inquire PDF Format
Supply Ability:80SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberAKF -2010V
    Brand NameYIMA
    Payment TermsT/T, paypal
    Features:
    1. The instrument USES the fully enclosed titration pool, can use all sorts of Karl fischer reagent, the system drift is extremely low, automatically change the solvent and discharge waste liquor, avoid toxic reagent to escape, avoid water infiltration in environment.Pipe joint adopts special nut and seal.
    2. Color LCD touch screen, graphical shortcut convenient and quick operation, test parameters setting method is simple and can store all the analysis results, a variety of results (water content, percentage, content of PPM, carr's reagent consumption) shows at the same time,
    3. The dynamic display of color titration curve, automatic memory measurement results, the determination results according to GMP/GLP requirements or print the report format output.
    4. The core patent technology, carefully designed titration using push on the piston burette, greatly reduce the equipment failure rate at the same time, also let the instrument to achieve an unprecedented titration accuracy. Wo work original patent piston head in - between 20
    and 40 ambient temperature are perfect cooperation and high accuracy measuring tube, blowing can drive piston movement without the slightest reagent leaks. Is created as much as 5 times of long service life than the other.
    5. New titration pool seal design, in addition to keep system low drift, also let a pool of toxic reagents cannot leak any, insure the safety of operator and environment. Wo work creation and injector patent technology is applicable to different forms such as solid, liquid/gas samples and sample. Optional microtiter cup, double platinum needle electrode without maintenance.
    6. Detail decides success or failure, carefully designed casing seal leakage and grooves that may never use. Because of the leakage may be reduced to one over ten thousand, however well guarantee is a firm concept of design.AKF series Karl fischer moisture meter no common similar instrument reagent leak into the instrument host to corrosion items within the host.
    7. Automatic measurement, advanced end algorithm, can use all sorts of brands at home and abroad Karl fischer reagent; Determination is simple, rapid and accurate;Environmental water drift automatic tracking, can be deducted automatically, to ensure that the analysis results are accurate;
    8. The instrument can realize: suction reagent, measurement, display, solvent inhalation, effluent discharge, the blender and stepless speed regulation, and other functions; Instrument condition, metering pump injection quantity, the current time, amount of drift parameters such as real-time display.
    9. The instrument according to the sample to adjust the titration speed, using titration control system has high precision, high accuracy ;Intelligent fault diagnosis, a hardware failure automatically stops running, protect important components; Using the unique patented technology of high-precision quantitative tube head and non-proliferation titration, ensuring that the system measurement results are accurate and steady operation and low failure rate, more than five times as much as key components life extension.
    10. AKF - 2010 - v contains a variety of data interface, the RS - 232 - c connection, network interface, USB interface; Optional miniature data special printer, may at any time to print analysis report.The report data can be exported.
    11. Intelligent reagent management system to realize automatic under the closed state to join the new reagents, also can automatically change the Karl fischer reagent, end-point, effective protection experiment personnel to direct contact with toxic solvents, prevent waste liquid bottle of overflow.

    Technical parameter
    1 Determination of water content range: 0.001 100%) can improve the precision (choose specific reagents and accessories
    2 Titration accuracy: 0.5 ul (20 ml burette)
    3 Results the resolution: 1 PPM
    4 Repeatability: ≥99.7% (10 mg water)
    5 Method of storage: six
    8 The determination results data storage: 200 group (export) in bulk can use mobile storage
    7 Titration components: patent piston head, optional 20 ml (standard), 10 ml, 5 ml long life and high precision burette, uv radiation shield
    Auxiliary function: touch screen detected automatically deduct drift, automatically to keep the end, the Chinese character input end, delay the titration, the custom, the titration curve,
    8 Waste liquid bottle overflow warning, auxiliary, data statistics, data export
    9 Sample time: 2 minutes on average
    10 Monitor: 7 "hd LCD touch screen
    11 Valves and piping material: teflon PTFE three-way two-way electromagnetic drive control valve, anti-corrosion resistance to ultraviolet light design, completely anticorrosive pipe, convenient fast plug connector, nut
    12 Using the environment temperature: + 5 to 40
    Using the environment humidity: ≤80%
     
  • Features:
    1. The instrument USES the fully enclosed titration pool, can use all sorts of Karl fischer reagent, the system drift is extremely low, automatically change the solvent and discharge waste liquor, avoid toxic reagent to escape, avoid water infiltration in environment.Pipe joint adopts special nut and seal.
    2. Color LCD touch screen, graphical shortcut convenient and quick operation, test parameters setting method is simple and can store all the analysis results, a variety of results (water content, percentage, content of PPM, carr's reagent consumption) shows at the same time,
    3. The dynamic display of color titration curve, automatic memory measurement results, the determination results according to GMP/GLP requirements or print the report format output.
    4. The core patent technology, carefully designed titration using push on the piston burette, greatly reduce the equipment failure rate at the same time, also let the instrument to achieve an unprecedented titration accuracy. Wo work original patent piston head in - between 20
    and 40 ambient temperature are perfect cooperation and high accuracy measuring tube, blowing can drive piston movement without the slightest reagent leaks. Is created as much as 5 times of long service life than the other.
    5. New titration pool seal design, in addition to keep system low drift, also let a pool of toxic reagents cannot leak any, insure the safety of operator and environment. Wo work creation and injector patent technology is applicable to different forms such as solid, liquid/gas samples and sample. Optional microtiter cup, double platinum needle electrode without maintenance.
    6. Detail decides success or failure, carefully designed casing seal leakage and grooves that may never use. Because of the leakage may be reduced to one over ten thousand, however well guarantee is a firm concept of design.AKF series Karl fischer moisture meter no common similar instrument reagent leak into the instrument host to corrosion items within the host.
    7. Automatic measurement, advanced end algorithm, can use all sorts of brands at home and abroad Karl fischer reagent; Determination is simple, rapid and accurate;Environmental water drift automatic tracking, can be deducted automatically, to ensure that the analysis results are accurate;
    8. The instrument can realize: suction reagent, measurement, display, solvent inhalation, effluent discharge, the blender and stepless speed regulation, and other functions; Instrument condition, metering pump injection quantity, the current time, amount of drift parameters such as real-time display.
    9. The instrument according to the sample to adjust the titration speed, using titration control system has high precision, high accuracy ;Intelligent fault diagnosis, a hardware failure automatically stops running, protect important components; Using the unique patented technology of high-precision quantitative tube head and non-proliferation titration, ensuring that the system measurement results are accurate and steady operation and low failure rate, more than five times as much as key components life extension.
    10. AKF - 2010 - v contains a variety of data interface, the RS - 232 - c connection, network interface, USB interface; Optional miniature data special printer, may at any time to print analysis report.The report data can be exported.
    11. Intelligent reagent management system to realize automatic under the closed state to join the new reagents, also can automatically change the Karl fischer reagent, end-point, effective protection experiment personnel to direct contact with toxic solvents, prevent waste liquid bottle of overflow.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com