AG-1900 Aerosol Generator Introduction: The AG-1900 aerosol generator can generate aerosol particles with various diameter distributions. When used in conjunction with a DP-30 or TDA-2I photometer, it can provide sufficient challenging particles to measure efficient filtration systems (flow range from 500-70000 CFM (833-120000 M3/H)). The function of the oil circuit insurance supply system and the AG-1900 aerosol generator with thermal switch is currently the safest aerosol generator. This is an enhanced aerosol generator that is more convenient for users to use, with temperature, working status, and pressure digital display and over limit alarm. Easy to operate, stable, suitable for certification, HEPA performance testing, and installation. Inert gas is required, suitable for AC220V ± 10PHZ power supply. The optional remote control supports reading the device's working status: atomization, standby, intake pressure, atomization pressure. characteristic: 1. Heating principle, high concentration aerosol output. 2. Can be applied to the flow rate of different air conditioning systems. 3. Internal overvoltage protection, overheating protection, triple safety protection 4. Protection: Temperature controllers imported from the United States, flow rates imported from the United States 5. Regulating valve - the choice of quality. 6. Overcomed leakage treatment. 7. The device comes with a drain valve, which facilitates the release of remaining aerosol liquids. Technical parameters: Heating or cooling time: 1-2 minutes Available traffic range: 500-70,000cfm Suspended particle concentration: 10ug/L; flow rate: 70000cfm Suspended particle concentration: 100ug/L; flow rate: 7000cfm grain: PAO、DOP、 Multi dispersed Occurrence method: Fever occurs Compressed air (inert): nitrogen, argon, carbon dioxide, or helium (50psi) Weight: Approximately 8kg Size: 40*17*27.3 Power Supply: AC220~240VAC,50/60HZ
Introduction: The AG-1900 aerosol generator can generate aerosol particles with various diameter distributions. When used in conjunction with a DP-30 or TDA-2I photometer, it can provide sufficient challenging particles to measure efficient filtration systems (flow range from 500-70000 CFM (833-120000 M3/H)). The function of the oil circuit insurance supply system and the AG-1900 aerosol generator with thermal switch is currently the safest aerosol generator. This is an enhanced aerosol generator that is more convenient for users to use, with temperature, working status, and pressure digital display and over limit alarm. Easy to operate, stable, suitable for certification, HEPA performance testing, and installation. Inert gas is required, suitable for AC220V ± 10PHZ power supply. The optional remote control supports reading the device's working status: atomization, standby, intake pressure, atomization pressure.