1 Sales AFS-9330 sequential injection atomic fluorescence photometer,Manufacturer
Position: Home > > Analytical instruments > Spectrometry > Atomic fluorescence spectrum > AFS-9330 sequential injection atomic fluorescence photometer

AFS-9330 sequential injection atomic fluorescence photometer

Product ID:FGyzyg019

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberAFS-9330
    Brand NameYIMA
    Payment TermsT/T, paypal
    Features:
    A dual-channel simultaneous determination of two elements, and is suitable for trace analysis of As, Se, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn, Cd,
    2 six light design, computer control automatically change the element lights;
    3 automatic built-in sequential injection pump injection system;
    4 can be a single standard automatic configuration of the standard curve, online automatic dilution of high concentrations of samples online automatically add reducing agent (masking agent) and other reagents;
    5 original double-beam dual-detector structure for atomic fluorescence, real-time monitoring of light source drift and fluctuations, improve the stability and reliability of the instrument; airtight new light system (better mercury);
    6 bundled pulse power supply to extend lamp life, increase sensitivity and signal to noise ratio;
    7 low temperature argon argon flame, shielded quartz atomizer;
    8 using 160-pole polar autosampler;
    9 POST, gas automatic control, automatic protection, automatic alarm system;
    10 with chemical vapor phase gas-liquid separation device, and the use of online automatically remove the potassium borohydride bubble technology;
    11 using atomic fluorescence measurement exhaust harmful element trap device;
    12 using mass flow meter air control module, gas flow control precision, accurate, continuous flow can be adjusted, consistent, stable and reliable; shutdown can automatically cut off gas;
    13 Powerful Chinese-English software operating system for automated system diagnostics, automated sample measurement, standard curve method measurement, multiple report formats and expert help systems, recommended best instrument conditions and preferred methods, and sample preparation, Standard solution with guidelines;
    14 supports multiple working curve, to achieve full data switching, support for copying, pasting and graphics storage;
    15 highly integrated single-board modular circuit design, the international popular high-integrated modular single-board circuit design;
    Specifications:
    Detection limit DL:
    AS, Se, Pb, Bi, Sb, Te, Sn: <0.01 μg / L
    Hg, Cd: <0.001 μg / L
    Ge: <0.05 μg / L
    Zn: <1.0 μg / L
    Au: <3.0 μg / L
    Relative standard deviation RSD: <1%
    Linear range: more than three orders of magnitude

  • Features:
    A dual-channel simultaneous determination of two elements, and is suitable for trace analysis of As, Se, Bi, Hg, Se, Te, Sn, Ge, Pb, Zn, Cd,
    2 six light design, computer control automatically change the element lights;
    3 automatic built-in sequential injection pump injection system;
    4 can be a single standard automatic configuration of the standard curve, online automatic dilution of high concentrations of samples online automatically add reducing agent (masking agent) and other reagents;
    5 original double-beam dual-detector structure for atomic fluorescence, real-time monitoring of light source drift and fluctuations, improve the stability and reliability of the instrument; airtight new light system (better mercury);
    6 bundled pulse power supply to extend lamp life, increase sensitivity and signal to noise ratio;
    7 low temperature argon argon flame, shielded quartz atomizer;
    8 using 160-pole polar autosampler;
    9 POST, gas automatic control, automatic protection, automatic alarm system;
    10 with chemical vapor phase gas-liquid separation device, and the use of online automatically remove the potassium borohydride bubble technology;
    11 using atomic fluorescence measurement exhaust harmful element trap device;
    12 using mass flow meter air control module, gas flow control precision, accurate, continuous flow can be adjusted, consistent, stable and reliable; shutdown can automatically cut off gas;
    13 Powerful Chinese-English software operating system for automated system diagnostics, automated sample measurement, standard curve method measurement, multiple report formats and expert help systems, recommended best instrument conditions and preferred methods, and sample preparation, Standard solution with guidelines;
    14 supports multiple working curve, to achieve full data switching, support for copying, pasting and graphics storage;
    15 highly integrated single-board modular circuit design, the international popular high-integrated modular single-board circuit design;
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com