AA7003N multi-parameter Blood Elemental Analyzer

Product ID:SHLCqt009

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberAA7003N
    Brand NameYM
    Payment TermsT/T, paypal
    Test method: Flame,graphite furnace,flame emission method,hydride generation method
    Wavelength accuracy: The wavelength accuracy of the instrument≤±0.5nm
    Wavelength 
    repeatability:
    Wavelength repeatability≤0.3nm
    Resolution: 0.2nm spectral line half-width of bandwidth measurement≤0.2nm±0.02nm
    Baseline stability: Baseline drift within 30min≤0.005Abs;
    The maximum instantaneous noise baseline within 30min≤0.005Abs
    Sensitivity: Flame:Copper concentration of 2.0μg/ml standard solution absorbance
     measurements≥0.200Abs;
    Graphite Furnace:Copper concentration 20ng/mL,10μL injection volume, Measuring the absorbance of standard solution≥0.04Abs
     
    The detection limit:
    Flame:The detection limit for Cu≤0.008μg/ml;
    Graphite Furnace:The detection limit for copper≤25pg;
    Determination of the detection limit of blood lead≤1µg/L;
    Blood lead detection limit of quantitation≤3µg/L.
         
     
    Repeatability: Flame:Copper measured RSD≤1%;
    Graphite Furnace:Copper measured RSD≤4%,
    the blood lead 100μg/L manual injector RSD≤5%,autosampler
     RSD≤3%.
    Absorbance error: Transmittance calibration value does not exceed ± 2% of the 
    corresponding absorbance.
    Edge wavelength 
    noise:
    The wavelength range 190-900nm,arsenic 193.7nm, 
    852.1nm wavelength cesium were measured instantaneous 
    noise<0.02Abs.
    Background correction 
    capability:
     
    Deuterium background correction,background absorption
     near 1Abs,the instrument has a 30 times higher than the 
    background correction capability.
    Optical slit: Five-speed slit -band spectra:0.1,0.2,0.4,1.0,2.0nm;
    The wavelength shift caused by the deviation≤0.3nm.
     
  • Flame:Copper concentration of 2.0μg/ml standard solution absorbance
     measurements≥0.200Abs;
    Graphite Furnace:Copper concentration 20ng/mL,10μL injection volume, Measuring the absorbance of standard solution≥0.04Abs

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com