Position: Home > > Analytical instruments > Spectrometry > Atomic absorption spectroscopy > AA-7003M atomic absorption spectrophotometer

AA-7003M atomic absorption spectrophotometer

Product ID:FGyzxs040

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberAA-7003M
    Brand NameBEIJINGDONGXIFENXIYIQI
    Payment TermsT/T, paypal
    AA-7003M atomic absorption spectrophotometer
    Features
    It can be switched freely, and can measure various elements such as lead, cadmium, zinc, copper, calcium, magnesium, iron, etc .; it is made of graphite with fast temperature rise, high temperature resistance and oxidation resistance-short time and long service life.
    Avoid systematic errors in results caused by temperature changes and improve the reliability of clinical blood lead detection.
    The double guarantee of screening and confirmation, you only need to add the sample to the special reagent, you can go to the machine, eliminating the complicated sample preparation process, fast, simple and eliminate pollution.
    No manual operation is required, saving time and effort, realizing unattended automatic analysis; customers can also manually detect as needed.
    Press the ignition button lightly (without the help of an igniter).
    Burner explosion-proof device, acetylene flow control and leakage alarm device, solenoid valve power off and air pressure insufficient automatic cut-off device.
    Without modification, more than 70 elements in various samples can be expanded to meet the requirements of clinical research.
    Quick input, convenient management and query of patient information, friendly interface, perfect reporting system, support standard LIS and HIS under HL7 protocol.
    Pure titanium atomization chamber with lost wax precision casting process has the advantages of corrosion resistance, oxidation resistance, high temperature resistance and long service life.
    Adopt ICP sequence test mode.
    Factors such as instrument vibration and high temperature changes in the environment do not affect the stability of the instrument. 
    Technical parameters
    Buckle background technology: Deuterium lamp buckle background
    Detection limit: Pb≤1µg / L
    Resolution: ≤0.2nm ± 0.02nm
    Repeatability (RSD): RSD≤3%
    Sensitivity: Graphite furnace method, copper mass concentration 20µg / mL, absorbance ≥0.04Abs
    Detector category: photomultiplier tube
    Optical system: single beam
    Monochromatic components: flat grating

  • AA-7003M atomic absorption spectrophotometer does not require manual operation, saving time and effort, and realizes unattended automatic analysis; customers can also manually detect according to needs. AA-7003M atomic absorption spectrophotometer adopts pure titanium atomization chamber with lost wax precision casting process, which has the advantages of corrosion resistance, oxidation resistance, high temperature resistance and long service life.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com