Features: 1 outer tube water temperature automatic control does not exceed ± 0.1 ℃ 2 inside and outside the barrel water temperature automatically adjust 3 automatic oxygenation, automatic release of oxygen bomb exhaust 4 automatically identify the bomb number 5 is the largest domestic automation calorimeter 6 touch screen operation mode, click the function button 7 data processing do not have to open another software can be carried out, 8 data processing function is rich, automatically calculate the average, very poor, standard deviation and other statistics 9 test data can be automatically sent to other computers for data management. 10. Reliable test, heat capacity <0.1% repeatability, long-term heat capacity stability <0.2% 11. Test accuracy, heat test repeatability and reproducibility is better than GB GB / T213-2003 requirements 12. Test from the number of tests and environmental temperature changes, there is no first test void 13. Reliable, military technology temperature control system and oxygenation system, a unique pulsator mixing technology, stirring more fully reliable Technical Parameters: Temperature resolution: 0.0001 ℃ Heat capacity precision: ≤ 0.1% Single complete test time: <15 min Heat capacity stability: ≤ 0.2% Weight: 90Kg Dimensions: 1807mm × 582mm × 445mm (double control) Power: 220V ± 22V, 50Hz ± 1Hz Power: computer <300W, calorimeter host <500W Test Range: 15.000MJ / kg (3500Cal / g) to 35.000MJ / kg (8400Cal / g)
Features: 1 outer tube water temperature automatic control does not exceed ± 0.1 ℃ 2 inside and outside the barrel water temperature automatically adjust 3 automatic oxygenation, automatic release of oxygen bomb exhaust 4 automatically identify the bomb number 5 is the largest domestic automation calorimeter 6 touch screen operation mode, click the function button 7 data processing do not have to open another software can be carried out, 8 data processing function is rich, automatically calculate the average, very poor, standard deviation and other statistics 9 test data can be automatically sent to other computers for data management. 10. Reliable test, heat capacity <0.1% repeatability, long-term heat capacity stability <0.2% 11. Test accuracy, heat test repeatability and reproducibility is better than GB GB / T213-2003 requirements 12. Test from the number of tests and environmental temperature changes, there is no first test void 13. Reliable, military technology temperature control system and oxygenation system, a unique pulsator mixing technology, stirring more fully reliable