Brief introduction
4600 atomic absorption spectrophotometer is functional control and data processing by PC and its dedicated program of single beam flame - graphite furnace tandem integration of instruments that can be used to determine the constants of various substances , trace , trace metals and content of semi-metallic elements.
The instrument provides a 1-9 point calibration standard concentration , can make a single standard slope retune with linear regression , curve fitting, linear and nonlinear measurement standard addition method , the mean baseline compensation and the relative standard deviation , and other functions the calibration curve can be stored in a computer call freedom.
Optional AS4020 graphite furnace autosampler , heated cooling water pump . Features
1. flame and graphite furnace furnace , graphite furnace power machine integration , no mechanical switch that is able to achieve flame and graphite furnace atomic determination .
2. The new plastic , smooth -shaped cavity spray chamber.
3.8 lighthouse automatic switching elements , which can be preheated lit eight lights , which can be accessed by a high-performance light elements .
4. Automatic lighthouse regulating device ( utility model patents ) .
5. Graphite furnace autosampler for up to 100 sample positions .
Fire System:
6. digital set acetylene flow control is more accurate , more convenient
7. safe operation of the entire system , regardless of power failure occurs, the flame abnormal combustion head pressure is low or does not match , the flame safety system will alarm and automatically shut off the gas , to prevent tempering , ensuring that operators and equipment from harm and damage.
Graphite furnace system :
8. Tomb furnace without water , breathe , can overheat alarm The main parameters:
Wavelength range : 190nm - 900nm
Spectral Bandwidth : 0.1,0.2,0.4,1.0,2.0nm five -speed automatic
Wavelength indication error : ± 0.10nm
Wavelength repeatability : ≤0.05nm
Static baseline drift : 0.002A / 30min (Cu)
Flame sensitivity : greater than 0.45Abs (Cu 2μg / ml)
Detection limit : ≤ 0.004μg / ml (Cu)
Precision : RSD≤0.5%
Graphite Furnace characteristic quantities : ≤0.5 × 10-12g (Cd)
Precision : RSD≤1% ( autosampler )
Brief introduction
4600 atomic absorption spectrophotometer is functional control and data processing by PC and its dedicated program of single beam flame - graphite furnace tandem integration of instruments that can be used to determine the constants of various substances , trace , trace metals and content of semi-metallic elements.
The instrument provides a 1-9 point calibration standard concentration , can make a single standard slope retune with linear regression , curve fitting, linear and nonlinear measurement standard addition method , the mean baseline compensation and the relative standard deviation , and other functions the calibration curve can be stored in a computer call freedom.
Optional AS4020 graphite furnace autosampler , heated cooling water pump .